1590 buckeye drive - milpitas, ca 95035 - tel: 408-432-9898 - fax: 408-432-1551 sales@remec.com - www.remec.com specifications subject to change without notice. specifications subject to change without notice. in-ghz remec frequency doubler high isolation, in-line output input 2.0 to 10.0 ghz output 4.0 to 20.0 ghz output (ghz) 4.0-18.0 4.0-20.0 4.0-10.0 4.0-20.0 4.0-10.0 10.0-20.0 4.0-20.0 input (ghz) 2.0-9.0 2.0-10.0 2.0-10.0 2.0-10.0 2.0-5.0 5.0-10.0 2.0-10.0 min 25 db 20 dbc typical 11.0 db 11.5 db 32 db 26 dbc 2.5:1 1.8:1 +11 dbm +17 dbm max 13.0 db 15.0 db fd96 fd97 conditions specifications electrical specifications (1) : parameter insertion loss: (2) fundamental isolation: (3) third harmonic suppression: (4) input vswr: input power: fd9 x sm x -1 notes: 1. specifications are guaranteed when tested as a doubler in a 50 ohm system at +25c with nominal input power. specifications indicated as typical are not guaranteed. 2. insertion loss typically degrades less than 0.5 db at +100c and improves less than 0.5 db at -55c. 3. fundamental isolation is referenced to the fundamental input. 4. third harmonic suppression is referenced to the second harmonic output. 5. for smh models, isolation loss for 2-10-0 ghz is 13.5 db max, fundamental isolation is 20 db min. typical performance at 25 c d = no cover h = with cover input power 6 = +11 dbm 7 = +17 dbm fd9 x sm h -1 fd9 x sm d -1 all dimensions are in inches and [mm]. 3-60 outline: smdc4 outline: smdt4
|